Job #102
Customer: 925 sq. ft. Residential House
City: St. Clair Shores, MI
Date Built: 1960
Energy Efficiency Improvement Opportunities
(Years payback is calculated by taking Estimated Cost / Estimated Annual Savings)
(Estimated cost includes labor, material, and installation)
- Duct repair in Basement - Estimated Annual Savings = $53 , 3 year payback
- Duct Sealing - Estimated Annual Savings = $53 , 3 year payback
- Air sealup - Estimated Annual Savings = $83, 6 year payback
- Replace Gas Furnace in Basement - Esitmated Annual Savings = $20, 10 year payback
- Add duct/pipe insulation - Estimated Annual Savings = $27, 13 year payback
- Insulate Floor (R30) - Estimated Annual Savings = $86, 16 year payback